Determine the excess water pressure in the pipe, if the pressure gauge reading rm = 0,025MPa. The connecting pipe is filled with water and air, as shown in the diagram, and H1 = 0.5 m; H2 = 3m.
How to change the gauge reading if at the same pressure in the connecting pipe full of water fill pipe (air release valve through K)? The height H3 = 5m.
Answer: PB = 0,05MPA, RM = 0.

Additional information

Making Word in accordance with the requirements ESKD with all the necessary drawings and explanations

Feedback

0
No feedback yet.
In order to counter copyright infringement and property rights, we ask you to immediately inform us at support@plati.market the fact of such violations and to provide us with reliable information confirming your copyrights or rights of ownership. Email must contain your contact information (name, phone number, etc.)