The closed reservoir (Fig. 1) is divided into two parts by a flat partition having a square hole at depth h with side a closed by a lid. The pressure above the liquid in the left part of the reservoir is determined by the reading of the pressure gauge pm, the air pressure in the right part is determined by the reading of the vacuum gauge pv. Determine the strength of hydrostatic pressure on the cover.
Given: liquid - spindle oil; pm = 0.15at = 14715Pa; pv = 0.08at = 7848Pa; h = 2.00.9 m; a = 0.18m; rat = 98100 Pa
Buy and download a ready-made solution.
Product Content: task solution in Word format.

Feedback

0
Period
1 month 3 months 12 months
0 0 0
0 0 0
In order to counter copyright infringement and property rights, we ask you to immediately inform us at support@plati.market the fact of such violations and to provide us with reliable information confirming your copyrights or rights of ownership. Email must contain your contact information (name, phone number, etc.)